Thawzall TCH250/400GTS



FEATURES
5-600FT HOSES
OVER 3 DAYS RUN TIME
RETURN TEMPERATURE INDICATORS ON ALL 5 ZONES
BI-DIRECTIONAL POWERED REEL WITH FREEWHEEL FEATURE
SIMPLE TO OPERATE WITH 1 SWITCH
HEATZONE FLUID DISTRIBUTION
1 SWITCH START UP with Digital Monitoring
HEAT ZONE FLUID DISTRIBUTION TECHNOLOGY
THREE WAY MIXING VALVE PROVIDES PRECISE TEMPERATURE OUTLET CONTROL. THE BEST FOR CONCRETE
CURING.
SPECIFICATIONS
Hose 5 – 600 ft Field Hoses (5/8” Hose)
Hose Unspool with one person
Supply Manifold 5 – 3/4” quick connect & 1 – 1” quick connect
Return Manifold 5 – 3/4” quick connect & 1 – 1” quick connect
Ground Thawing Capacity up to 6,000 ft2
Concrete Curing Capacity up to 12,000 ft2
Temporary Heating Capacity 12,000 ft2 (Varies with R-Value)
Field Pump 1/2 Hp closed Loop Centrifugal
Fuel Tank 150 US GAL DOUBLE WALL TANK
Run Time Up to 100 Hours (with Genset)
Fuel Consumption TCH 250 = 2.06 GPH, Genset = .55 GPH
Interior Lights Standard for ease of night operation
Heater Capacity Diesel 280,000 BTU/H Heating Fuel Input
Electrical Requirements 1 – 120V AC 20A Circuits
Generator (Optional) 1 – 7,000W
Hitch 2 5/16” Ball (Pintle also available)
Dimensions 170”x84”x93”
Weight (Fuel Full) 5900 lbs
THAWZALL TCH250 W/ Generator
- Better flow and heat transfer with newly designed “series flow pattern”
- Ease-of-use and newly designed Control box on rear passenger side
- Easier operator interface with all controls in one place
- Easy OFF-ON switch eliminates need for training
- More accurate cold weather concrete curing with simple temperature setting
- Alert for fuel gauge and low water for quick trouble shooting
- Faster thawing due to flow is increases from larger sized and shorter piping
- New Power-In-Power-out and free-wheeling feature for reel operation with dynamic brake
- L x W x H
- 170in x 84in x 97in
- Weight w/fuel & fluid
- 5,600lbs
- Optional Generator
- 310lbs
- Fuel Capacity
- 160gal
- HTF (Heat Transfer Fluid)
- 122gal
- One – 1/2 hp Pump
- Closed Loop Centrifugal
- Hose Length (5 zones x 600’)
- 3,000ft
- Electrical, GFI
- 20 amp x 120 vac
- HTF Pumpability
- -80°F
- Fuel
- Winter blend diesel or #1 fuel oil
- Hitch Choices
- Forged, Stamped, or Pintle
- Diesel Generator
- 7.0 KWH Liquid Cooled
- THAW frozen ground
- 3,000-6,000 sq ft
- CURE concrete
- 6,000 sq ft
- with accessories
- 18,000 sq ft max
- FROST prevention
- 9,000 sq ft
- with accessories
- 27,000 sq ft max
- HEAT buildings
- 400,000 cu ft
- Input/Output
- 280/234 MBH*
- Operating Range
- 70-200°F
- Operating Pressure
- 1-5 psi
- Fuel Consumption (max)
- 1.75 gph
- Run Time
- 3+ days
- Pump Capacity
- 30/1800 gpm/gph